-
X-Received: by 10.140.102.82 with SMTP id v76mr460071qge.25.1425930322760; Mon, 09
Mar 2015 12:45:22 -0700 (PDT)
X-Received: by 10.140.102.82 with SMTP id v76mr460071qge.25.1425930322760; Mon, 09
Mar 2015 12:45:22 -0700 (PDT)
Path: news-archive.icm.edu.pl!agh.edu.pl!news.agh.edu.pl!news.cyf-kr.edu.pl!news.nask
.pl!news.nask.org.pl!news.unit0.net!feeds.phibee-telecom.net!newsfeed.xs4all.nl
!newsfeed3a.news.xs4all.nl!xs4all!newspeer1.nac.net!border2.nntp.dca1.giganews.
com!nntp.giganews.com!hl2no5622565igb.0!news-out.google.com!db6ni44597igc.0!nnt
p.google.com!hl2no8098073igb.0!postnews.google.com!glegroupsg2000goo.googlegrou
ps.com!not-for-mail
Newsgroups: pl.misc.elektronika
Date: Mon, 9 Mar 2015 12:45:22 -0700 (PDT)
In-Reply-To: <c...@m...uni-berlin.de>
Complaints-To: g...@g...com
Injection-Info: glegroupsg2000goo.googlegroups.com; posting-host=83.28.42.1;
posting-account=4JAi3QoAAAAkbBNUGR1Cec0-dtcxIBjx
NNTP-Posting-Host: 83.28.42.1
References: <c...@m...uni-berlin.de>
<b...@g...com>
<c...@m...uni-berlin.de>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <f...@g...com>
Subject: Re: Pytanie Altium Designer
From: m...@g...com
Injection-Date: Mon, 09 Mar 2015 19:45:22 +0000
Content-Type: text/plain; charset=ISO-8859-2
Content-Transfer-Encoding: quoted-printable
Lines: 36
Xref: news-archive.icm.edu.pl pl.misc.elektronika:679195
[ ukryj nagłówki ]> Mamy na przykład element w obudowie TO3, choćby staruszek 2N3055. Ma
> mocowanie na dwie śruby, oba punkty to kolektor, jeden i ten sam.
> Zrobiłem schemat na czymś takim i go rutuję. Przy rutowaniu wychodzi, że
> część elementów wygodniej jest podłączyć do jednej strony, a inne do
> drugiej. Sieć łączy się przez obudowę tranzystora. Altium mi na to nie
> pozwala, chyba, że połączę oba punkty na PCB. Taką sytuację mam też w
> przypadku gotowych modułów (choćby popularny Pololu USB-RS232), czy też
> coponiektórych gniazd.
> To, co mnie aktualnie upiernicza to zaciski śrubowe. Pojedyncze zaciski
> mają dwie nogi rozstawione o 200mil. Wygodniej by mi było, gdybym nie
> musiał robić połączenia na PCB między tymi nogami, ale Altium mnie do
> tego zmusza.
>
> Waldek
Czy to przypadkiem nie rozwiązuje problemu?
...
Use this field to provide a jumper connection identification number (range of 1 -
1000) to the pad when you are using a jumper connection on the PCB. A jumper
connection uses a wire to physically connect pads on a PCB, and not using tracks or
electrical objects on the board. The Jumper ID value tells Altium Designer which pads
to treat as 'connected'. A jumper connection can only be created amongst the pads
within a component footprint. The pads used must use the same Jumper ID value and
must also share the same net. A jumper connection is shown as a curved connection
line in the PCB Editor.
2m
Następne wpisy z tego wątku
- 09.03.15 21:03 2m
- 10.03.15 11:14 Waldemar
- 10.03.15 14:23 Dariusz Dorochowicz
- 10.03.15 15:08 Waldemar
- 11.03.15 10:22 Dariusz Dorochowicz
Najnowsze wątki z tej grupy
- Podstawa bezpiecznikowa jako rozłącznik DC
- Napięcie akumulatora wyłączające UPS / jakie nowe akumulatory do UPS?
- nawigacja satelitarna
- SmartLife/Tuya i osuszanie -- mordowanie z zimną krwią...
- Głośnik piezoelektryczny
- Mala autonomiczna kamera monitoringu
- czas na emeryturę i EB
- Generowanie sumy kontrolnej z fragmentu pliku bin
- Re: Mala autonomiczna kamera monitoringu
- HDMI
- Re: Mala autonomiczna kamera monitoringu
- Kamera monitoringu z kartą SIM
- Re: Kamera monitoringu z kartą SIM
- Re: Kamera monitoringu z kartą SIM
- skąd my to znamy
Najnowsze wątki
- 2024-06-29 eSIM, praktyczne doświadczenia z różnymi operatorami?
- 2024-06-30 1250 euro za rezygnacje z posiadania samochodu
- 2024-06-29 poszedł na czerwonym i uderzył w motur
- 2024-06-29 Tesla to wóz dla mnie
- 2024-06-30 Podstawa bezpiecznikowa jako rozłącznik DC
- 2024-06-29 Napięcie akumulatora wyłączające UPS / jakie nowe akumulatory do UPS?
- 2024-06-30 Basen i chłodzenie w w wentylacji mechanicznej
- 2024-06-29 na chuj mieć dom?
- 2024-06-29 Marki => ERP Implementer <=
- 2024-06-29 Warszawa => SQL Database Developer <=
- 2024-06-29 Poznań => Senior PHP Developer (Symfony) <=
- 2024-06-29 Warszawa => Senior Cloud DevOps Engineer (Azure) <=
- 2024-06-29 Gdańsk => Kierownik Działu Spedycji Międzynarodowej <=
- 2024-06-29 Ulm => IT Network Engineer <=
- 2024-06-29 Warszawa => Full Stack .Net Engineer <=