eGospodarka.pl
eGospodarka.pl poleca

eGospodarka.plGrupypl.misc.elektronikaLead timesRe: Lead times
  • Data: 2021-09-14 10:07:07
    Temat: Re: Lead times
    Od: Piotr Wyderski <b...@p...com> szukaj wiadomości tego autora
    [ pokaż wszystkie nagłówki ]

    Irek.N. wrote:

    > Z Twojego opisu odniosłem wrażenie, że nadrzędną cechą jest fakt
    > niemożliwości połączenia styku NO i NC.

    https://pl.mouser.com/datasheet/2/16/relacat-2307308
    .pdf

    Forced-Guided Contacts: Electro-mechanical relay
    contacts that are mechanically linked together, so
    that when the relay coil is energized or de-energized,
    all of the linked contacts move together. If one set of
    contacts in the relay becomes immobilized, no other
    contact of the same relay will be able to move. An
    open-contact gap > 0.5 mm ( 0.02 in.) is maintained
    during life of the relay, even with malfunction, and at
    1.6 x Nominal Voltage. Forced-Guided contacts are
    also known as captive contacts, positive-guided
    contacts, or locked contacts. They are used in
    Safety Relays.

    Pozdrawiam, Piotr

Podziel się

Poleć ten post znajomemu poleć

Wydrukuj ten post drukuj


Następne wpisy z tego wątku

Najnowsze wątki z tej grupy


Najnowsze wątki

Szukaj w grupach

Eksperci egospodarka.pl

1 1 1

Wpisz nazwę miasta, dla którego chcesz znaleźć jednostkę ZUS.

Wzory dokumentów

Bezpłatne wzory dokumentów i formularzy.
Wyszukaj i pobierz za darmo: