    > Sprawdź normę 62368-1 i się sam przekonaj.
    >

    Ok. poniżej dwa cytaty z normy 62368-1

    3.3.15.3
    class II equipment
    equipment in which protection against electric shock does not rely on basic
    insulation only,
    but in which a supplementary safeguard is provided, there being no provision for
    protective
    earthing or reliance upon installation conditions

    4.2.4 Energy source classification by declaration
    The manufacturer may declare:
    - a class 1 energy source to be either a class 2 energy source or a class 3 energy
    source;
    - a class 2 energy source to be a class 3 energy source.
    A neutral conductor is considered to be a class 3 electrical energy source.


    Ja mam np. takie urządzenie gdzie między częściami czynnymi a częścią wtórną dostępną
    dla człowieka jest izolacja wzmocniona. PE jest połączone do strony wtórnej ze
    względów funkcjonalnych a nie bezpieczeństwa ale między częściami czynnymi a PE też
    mam izolację wzmocnioną. W świetle powyższego jednak bym uznał, że to urządzenie jest
    w klasie II.

    --
    Antek