eGospodarka.pl
eGospodarka.pl poleca

eGospodarka.plGrupypl.misc.elektronikaZasilacz MEANWELL EPP400 › Re: Zasilacz MEANWELL EPP400
  • Path: news-archive.icm.edu.pl!news.icm.edu.pl!newsfeed.pionier.net.pl!news.samoylyk.n
    et!news.uzoreto.com!newsreader4.netcologne.de!news.netcologne.de!peer03.ams1!pe
    er.ams1.xlned.com!news.xlned.com!peer02.ams4!peer.am4.highwinds-media.com!news.
    highwinds-media.com!newsfeed.neostrada.pl!unt-exc-01.news.neostrada.pl!unt-spo-
    b-01.news.neostrada.pl!news.neostrada.pl.POSTED!not-for-mail
    Subject: Re: Zasilacz MEANWELL EPP400
    Newsgroups: pl.misc.elektronika
    References: <5fd7ab77$0$518$65785112@news.neostrada.pl>
    <5fddf262$0$543$65785112@news.neostrada.pl>
    From: JS <b...@p...onet.pl>
    Date: Sun, 20 Dec 2020 20:59:13 +0100
    User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:78.0) Gecko/20100101
    Thunderbird/78.6.0
    MIME-Version: 1.0
    In-Reply-To: <5fddf262$0$543$65785112@news.neostrada.pl>
    Content-Type: text/plain; charset=utf-8; format=flowed
    Content-Language: pl
    Content-Transfer-Encoding: 8bit
    Lines: 37
    Message-ID: <5fdfad19$0$522$65785112@news.neostrada.pl>
    Organization: Telekomunikacja Polska
    NNTP-Posting-Host: 37.47.57.159
    X-Trace: 1608494361 unt-rea-a-01.news.neostrada.pl 522 37.47.57.159:19249
    X-Complaints-To: a...@n...neostrada.pl
    X-Received-Bytes: 2671
    Xref: news-archive.icm.edu.pl pl.misc.elektronika:760331
    [ ukryj nagłówki ]

    W dniu 2020-12-19 o 13:30, Andrzej W. pisze:
    > W dniu 14.12.2020 o 19:14, JS pisze:
    >> Używał ktoś może zasilacza MEANWELL serii EPP400? Tam m.in. jest
    >> wyjście 12V/0.5A dla wentylatora. U mnie na tym wyjściu nie ma
    >> napięcia. Czy tam jest jakaś automatyka, która uruchamia wentylator
    >> dopiero jak się zasilacz nagrzeje? Karta katalogowa jest bardzo uboga
    >> w tym temacie.
    >> Pozdrawiam
    >> JS
    >
    > Napisz do nich, z tego co pamiętam odpisują.
    >


    Znalazłem taki text w FAQ na ich stronie (może się kiedyś komuś przyda):

    Cooling fans have a relatively shorter lifetime (typical MTTF, Mean Time
    To Failure, of around 5000-100000 hours) compared with other components
    of power supply. As a result, changing operating method of the fans can
    extend the operation hours. The most common control schemes are shown as
    below:

    Temperature control: if the internal temperature of a power supply,
    detected by a temperature sensor, is over the threshold, the fan will
    start working at full speed, whereas, if the internal temperature is
    less than the set threshold, the fan will stop working or run at half
    speed. In addition, cooling fans in some power supplies are controlled
    by a non-linear control method whereby fan speed can be changed with
    different internal temperatures synchronously.
    Load control: if the loading of a power supply is over the
    threshold, the fan will start working at full speed, whereas, if the
    loading is less than the set threshold, the fan will stop working or run
    at half speed.

    Temat rozwiązany, dzięki za sugestie.
    Pozdrawiam Świątecznie.
    JS