eGospodarka.pl
eGospodarka.pl poleca

eGospodarka.plGrupypl.misc.telefoniaZasilanie telefonw Cisco z zasilaczy AvayaRe: Zasilanie telefonw Cisco z zasilaczy Avaya
  • Path: news-archive.icm.edu.pl!news.icm.edu.pl!news.onet.pl!not-for-mail
    From: J.F. <j...@p...onet.pl>
    Newsgroups: pl.misc.telefonia
    Subject: Re: Zasilanie telefonw Cisco z zasilaczy Avaya
    Date: Sat, 29 May 2010 13:46:54 +0200
    Organization: -
    Lines: 20
    Message-ID: <j...@4...com>
    References: <htpdd1$odf$1@news.onet.pl>
    NNTP-Posting-Host: h82-143-187-50-static.e-wro.net.pl
    Mime-Version: 1.0
    Content-Type: text/plain; charset=ISO-8859-2
    Content-Transfer-Encoding: 8bit
    X-Trace: news.onet.pl 1275133609 23540 82.143.187.50 (29 May 2010 11:46:49 GMT)
    X-Complaints-To: n...@o...pl
    NNTP-Posting-Date: Sat, 29 May 2010 11:46:49 +0000 (UTC)
    X-Newsreader: Forte Agent 1.93/32.576 English (American)
    Xref: news-archive.icm.edu.pl pl.misc.telefonia:231210
    [ ukryj nagłówki ]

    On Fri, 28 May 2010 23:43:01 +0200, Adam 'Adak' Kępiński wrote:
    >Jak wyglada sprawa zasilania telefonow Cisco (np. 7941) z zasilaczy
    >Avaya [pomijam PoE z jakis PoEowych switchy]?
    >Ps. Wyprowadzenie 7 i 8 zyly z kabla wpietego w zasilacz A i wpiecie ich
    >w gniazdo zasilajace Ciskacza wlacza telefon, wiec nie o wydajnosc
    >zasilaczy chodzi.

    Na pewno zyly te same ?

    http://en.wikipedia.org/wiki/PoE

    Jesli to standard B, to powienienes wypiac 7i8, oraz 4i5.
    Moze to efekt polaczenia pozostalych par z masa ?

    Sa tam tez dwa protokoly opisane - czyby ktorys zawodzil ?

    J.



Podziel się

Poleć ten post znajomemu poleć

Wydrukuj ten post drukuj

Najnowsze wątki z tej grupy


Najnowsze wątki

Szukaj w grupach

Eksperci egospodarka.pl

1 1 1

Wpisz nazwę miasta, dla którego chcesz znaleźć jednostkę ZUS.

Wzory dokumentów

Bezpłatne wzory dokumentów i formularzy.
Wyszukaj i pobierz za darmo: