eGospodarka.pl
eGospodarka.pl poleca

eGospodarka.plGrupypl.misc.elektronika0-10V vs. 4-20mA/0-20mARe: 0-10V vs. 4-20mA/0-20mA
  • Path: news-archive.icm.edu.pl!news.rmf.pl!agh.edu.pl!news.agh.edu.pl!news.onet.pl!not
    -for-mail
    From: J.F. <j...@p...onet.pl>
    Newsgroups: pl.misc.elektronika
    Subject: Re: 0-10V vs. 4-20mA/0-20mA
    Date: Tue, 02 Mar 2010 22:44:06 +0100
    Organization: -
    Lines: 30
    Message-ID: <8...@4...com>
    References: <hm6u7s$q2g$1@node1.news.atman.pl> <hm6vc7$68i$1@news.onet.pl>
    <hm70hh$qad$1@node1.news.atman.pl> <hm89p6$p1l$1@news.onet.pl>
    <hm8a85$c9$1@node1.news.atman.pl> <hm8d0a$21q$1@news.onet.pl>
    <hm8qqk$7nn$1@news.onet.pl>
    NNTP-Posting-Host: h82-143-187-50-static.e-wro.net.pl
    Mime-Version: 1.0
    Content-Type: text/plain; charset=ISO-8859-2
    Content-Transfer-Encoding: 8bit
    X-Trace: news.onet.pl 1267566245 30623 82.143.187.50 (2 Mar 2010 21:44:05 GMT)
    X-Complaints-To: n...@o...pl
    NNTP-Posting-Date: Tue, 2 Mar 2010 21:44:05 +0000 (UTC)
    X-Newsreader: Forte Agent 1.93/32.576 English (American)
    Xref: news-archive.icm.edu.pl pl.misc.elektronika:583567
    [ ukryj nagłówki ]

    On Fri, 26 Feb 2010 16:53:35 +0100, Mario wrote:
    >> Wszystkie w/w są zbyt mało dokładne. Jak ci 5 stopni dokładności
    >> wystarczy to bierz.
    >> Termopar jest wiele rodzajów.
    >> Na 20 st. to termistor czy jakiś elektroniczny z diodą Kelvina.
    >
    >Twoim zdaniem PT100 da 5 stopni dokładności?

    Dokladnosc czujnika to jest osobny temat.
    Ale przy pradzie np 1mA Pt100 daje zmiane 390uV/K.
    A termopara jednak 10x mniej.

    A jak sie latwo mierzy uV ..

    P.S. Ciekawie pisza w wikipedii

    http://en.wikipedia.org/wiki/Resistance_thermometer

    Commercial platinum grades are produced which exhibit a change of
    resistance of 0.385 ohms/°C (European Fundamental Interval) The sensor
    is usually made to have a resistance of 100ohm at 0 °C. This is
    defined in BS EN 60751:1996 (taken from IEC 60751:1995) . The American
    Fundamental Interval is 0.392 ohm/°C, based on using a purer grade of
    platinum than the European standard. The American standard is from the
    Scientific Apparatus Manufacturers Association (SAMA), who are no
    longer in this standards field. As a result the "American standard" is
    hardly the standard even in the US.

    J.