    Subject: Nagły problem z JTAGiem i OpenOCD
    Date: Sun, 06 Nov 2011 21:58:18 +0100
    Organization: "Portal Gazeta.pl -> http://www.gazeta.pl"
    Lines: 67
    Message-ID: <j96sdb$qud$1@inews.gazeta.pl>
    NNTP-Posting-Host: hmk227.internetdsl.tpnet.pl
    Mime-Version: 1.0
    Content-Type: text/plain; charset=ISO-8859-2; format=flowed
    Content-Transfer-Encoding: 8bit
    X-Trace: inews.gazeta.pl 1320613099 27597 79.188.62.227 (6 Nov 2011 20:58:19 GMT)
    X-Complaints-To: u...@a...pl
    NNTP-Posting-Date: Sun, 6 Nov 2011 20:58:19 +0000 (UTC)
    X-User: konoppo
    User-Agent: Mozilla/5.0 (X11; Linux x86_64; rv:7.0.1) Gecko/20110929
    Thunderbird/7.0.1
    Xref: news-archive.icm.edu.pl pl.misc.elektronika:619973
    [ ukryj nagłówki ]

    Witam

    Po aktualizacji Ubuntu pojawiły się problemy z używaniem JTAGa
    (Turtelizer 2) przez OpenOCD. Wywołanie polecenia:

    openocd -f interface/turtelizer2.cfg -f target/stm32f1x.cfg

    I wszystko jest OK. Łączę się (telnet localhosr 4444) i mogę wydawać
    różne polecenia, robić halt itp. Gorzej, gdy wydam polecenie reset.
    Wówczas na ekranie dostaję coś takiego:
    JTAG tap: stm32.cpu tap/device found: 0x3ba00477 (mfg: 0x23b, part:
    0xba00, ver: 0x3)
    JTAG tap: stm32.bs tap/device found: 0x06414041 (mfg: 0x020, part:
    0x6414, ver: 0x0)
    Invalid ACK 0 in JTAG-DP transaction


    in procedure 'reset'
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 100ms

    I później co chwilę tego typu komunikaty. Całość wygląda tak:
    > reset halt
    JTAG tap: stm32.cpu tap/device found: 0x3ba00477 (mfg: 0x23b, part:
    0xba00, ver: 0x3)
    JTAG tap: stm32.bs tap/device found: 0x06414041 (mfg: 0x020, part:
    0x6414, ver: 0x0)
    Invalid ACK 0 in JTAG-DP transaction


    in procedure 'reset'
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 100ms
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 300ms
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 700ms
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 1500ms
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 3100ms
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 6300ms
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 6300ms
    stm32.cpu -- clearing lockup after double fault
    Polling target failed, GDB will be halted. Polling again in 6300ms
    > shutdown
    shutdown command invoked
    > Connection closed by foreign host.

    Komendę shutdown wydałem ja :). Powiedzcie mi, gdzie szukać błędu?
    Korzystam z "wbudowanych" w OpenOCD plików konfiguracyjnych i wersji:

    openocd --version
    Open On-Chip Debugger 0.5.0 (2011-08-26-10:36)
    Licensed under GNU GPL v2
    For bug reports, read
    http://openocd.berlios.de/doc/doxygen/bugs.html

    Podobne problemy mam z innym uC (LPC2378), natomiast na innym komputerze
    (z Windows Vista) wszystko działa z LPC2378, a z STM nie próbowałem. Co
    jest nie tak??!!

    --
    Pozdrawiam
    Konop

Podziel się

Poleć ten post znajomemu poleć

Wydrukuj ten post drukuj


Następne wpisy z tego wątku

Najnowsze wątki z tej grupy


Najnowsze wątki

Szukaj w grupach

Eksperci egospodarka.pl

1 1 1

Wpisz nazwę miasta, dla którego chcesz znaleźć jednostkę ZUS.

Wzory dokumentów

Bezpłatne wzory dokumentów i formularzy.
Wyszukaj i pobierz za darmo: